Re: BQL support in gianfar causes network hickup
From: Paul Gortmaker <hidden>
Date: 2013-02-06 01:56:11
On Tue, Feb 5, 2013 at 8:00 AM, Keitel, Tino (ALC NetworX GmbH) [off-list ref] wrote:
On Di, 2012-11-27 at 05:32 -0800, Eric Dumazet wrote:quoted
On Tue, 2012-11-27 at 13:42 +0100, Keitel, Tino (ALC NetworX GmbH) wrote:quoted
On Di, 2012-11-27 at 04:36 -0800, Eric Dumazet wrote:quoted
Can you reproduce the problem using a single cpu ?Yes, it is a single-CPU system.Can you reproduce the problem without PTP running, or disabled in the driver ? (comment the "priv->hwts_tx_en = 1;" line)I can't reproduce it with that line commented. However, so far I was only able to reproduce it when starting the ptp2 client, so maybe this is connected.
How critical is ptp2 for this? And/or the platform details? I can try and reproduce it on an mpc8349 system and/or an mpc8548 system (and even an mpc8641D system) but I'd rather know that was a meaningful chase and not a snipe hunt before going there. So, in that respect, a "If you run this, you will get this" type of error message would be good. I understand that may be too idealistic, though. Thanks, Paul. --
quoted
By the way are any errata flagged in gfar_detect_errata() ?This is from dmesg: fsl-gianfar e0024000.ethernet: enabled errata workarounds, flags: 0x7 0x7 would be GFAR_ERRATA_74, GFAR_ERRATA_76 and GFAR_ERRATA_A002 according to drivers/net/ethernet/freescale/gianfar.h. Regards, Tino