Rob,
On Thu, 11 Oct 2012 10:46:57 -0500, Rob Herring wrote:
quoted
+Required properties:
+- compatible: should be "marvell,neta".
This should be more specific such as "marvell,armada-xp-neta".
Or use 370 instead of xp. It should be which ever chip came first.
quoted
+- reg: address and length of the register set for the device.
+- interrupts: interrupt for the device
+- phy-mode: String, operation mode of the PHY interface. Supported
+ values are "sgmii" and "rmii".
+- phy-addr: Integer, address of the PHY.
+- device_type: should be "network".
Drop this. device_type is not used for FDT.
quoted
+- clock-frequency: frequency of the peripheral clock of the SoC.
+
+Example:
+
+eth@d0070000 {
Should be ethernet@...
Thanks for your comments. Will fix in v3.
Best regards,
Thomas
--
Thomas Petazzoni, Free Electrons
Kernel, drivers, real-time and embedded Linux
development, consulting, training and support.
http://free-electrons.com