On Mon, Sep 10, 2012 at 05:45:49PM +0200, Christophe Leroy wrote:
This patch adds proper handling of the buggy revision A2 of LXT973 phy, adding
precautions linked to ERRATA Item 4:
Item 4: MDIO Interface and Repeated Polling
Problem: Repeated polling of odd-numbered registers via the MDIO interface
randomly returns the contents of the previous even register.
Implication: Managed applications may not obtain the correct register contents
when a particular register is monitored for device status.
Workaround: None.
Status: This erratum has been previously fixed (in rev A3)
Hmm. Were did you get the hardware from? We have been using LXT973 in
our products and the A2 was replaced by A3 in 2003.
Best regards,
Lutz
--
Dr.-Ing. Lutz Jänicke
CTO
Innominate Security Technologies AG /protecting industrial networks/
tel: +49.30.921028-200
fax: +49.30.921028-020
Rudower Chaussee 13
D-12489 Berlin, Germany
www.innominate.com
Register Court: AG Charlottenburg, HR B 81603
Management Board: Dirk Seewald
Chairman of the Supervisory Board: Christoph Leifer