Thread (2 messages) 2 messages, 2 authors, 2011-08-05

Re: [PATCH net-next 6/6] be2net: fix to set ecmd->autoneg correctly

flat view

From: Ben Hutchings <hidden>
Date: 2011-08-05 21:52:01

On Fri, 2011-08-05 at 15:01 -0500, Ajit Khaparde wrote:
Set the autonegotation settings correctly based on the port speed.
[...]

Autonegotiation and multi-speed are two entirely different things.

Selecting a single speed doesn't mean turning autoneg off.  If you
enable only 1000BASE-T or only 10GBASE-T, the PHY must still go through
autoneg to determine whether it is the clock master for the link.

Enabling multiple speeds doesn't mean turning autoneg on.  An SFP+ slot
can take 1G and 10G modules but the modules generally won't support
autoneg.

Ben.

-- 
Ben Hutchings, Staff Engineer, Solarflare
Not speaking for my employer; that's the marketing department's job.
They asked us to note that Solarflare product names are trademarked.