Thread (3 messages) flat view 3 messages, 2 authors, 2011-06-10

CRC endianess problem on DGE-510T

From: Daniel Hellstrom <hidden>
Date: 2011-06-10 10:55:43
Subsystem: networking drivers, the rest · Maintainers: Andrew Lunn, "David S. Miller", Eric Dumazet, Jakub Kicinski, Paolo Abeni, Linus Torvalds

Hello,

I'm having problems with the PCI network board D-LINK DGE-510T on 
SPARC32/LEON. The CRC calculated by ether_crc_le() does not match the 
CRC, however after swapping the result it matches. This is the same 
behaviour with the 3 boards I have. After applying the patch below 
everything works.

Does anyone know if this is a correct patch or has had similar problems 
on big endian machines?

Daniel




From: Daniel Hellstrom <redacted>
Date: Wed, 6 Apr 2011 15:01:44 +0200
[PATCH] dl2k: EEPROM CRC calculation wrong endianess on bigendian machine

Signed-off-by: Daniel Hellstrom <redacted>
---
 drivers/net/dl2k.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/drivers/net/dl2k.c b/drivers/net/dl2k.c
index c445457..4bbbd7b 100644
--- a/drivers/net/dl2k.c
+++ b/drivers/net/dl2k.c
@@ -346,7 +346,7 @@ parse_eeprom (struct net_device *dev)
        if (np->pdev->vendor == PCI_VENDOR_ID_DLINK) {  /* D-Link Only */
                /* Check CRC */
                crc = ~ether_crc_le (256 - 4, sromdata);
-               if (psrom->crc != crc) {
+               if (psrom->crc != cpu_to_le32(crc)) {q
                        printk (KERN_ERR "%s: EEPROM data CRC error.\n",
                                        dev->name);
                        return -1;
--
1.5.4