From: "Matt Carlson" <redacted>
Date: Thu, 20 Dec 2007 14:59:56 -0800
This patch adds two functions designed to convert abstract TX & RX
flow control parameters to 1000-BaseT and 1000-BaseX autonegotiation
advertisements. Code that uses standard definitions which statically
advertises TX & RX flow control has been replaced with code that
configures the advertisements based on administrator dictated
preferences.
Signed-off-by: Matt Carlson <redacted>
Signed-off-by: Michael Chan <mchan@broadcom.com>
APplied.