[ BCCed reporter in case he wants to weigh in on the issue ]
On Sun, 08 Aug 2004 21:53:57 +0200, Manfred Spraul wrote:
Roger wrote:
quoted
PHYs may come up isolated. Make sure we can send data to them. This code
section needs a clean-up, but I prefer to merge this fix in isolation.
What was the phyid value for the isolated PHYs?
I suspect it was 0, because another suggestion in the same message was to
start scanning at 0 rather than 1 (obsolete with current via-rhine code).
I know that PHYs go into isolate mode if the startup id is wired to 0,
Wouldn't that be s/go/can go/ ?
but I haven't figured out what's necessary to initialize them: Just
clear the isolate bit or is it necessary to set the id to a nonzero value.
The proposed fix apparently worked for the PHY in question (LSI Logic
80225).
Roger