Re: [PATCH v3 3/6] staging: r8188eu: add error handling of rtw_read8
From: Dan Carpenter <hidden>
Date: 2021-08-27 09:07:35
Also in:
linux-staging
From: Dan Carpenter <hidden>
Date: 2021-08-27 09:07:35
Also in:
linux-staging
On Tue, Aug 24, 2021 at 10:27:27AM +0300, Pavel Skripkin wrote:
@@ -83,7 +83,12 @@ int proc_get_read_reg(char *page, char **start, switch (proc_get_read_len) { case 1: - len += snprintf(page + len, count - len, "rtw_read8(0x%x)=0x%x\n", proc_get_read_addr, rtw_read8(padapter, proc_get_read_addr)); + error = rtw_read8(padapter, proc_get_read_addr, (u8 *) &tmp); + if (error) + return len; + + len += snprintf(page + len, count - len, "rtw_read8(0x%x)=0x%x\n", + proc_get_read_addr, (u8) tmp); break;
Oh my goodness... :P If you look at what proc_get_read_addr is, it turns out it's a 32bit address which is controlled by the user in proc_set_read_reg(). LOL! Just a giant security hole. My advise is just delete this dead code. No one is using it so how necessary can it be? regards, dan carpenter