Re: [PATCH 01/19] btrfs: require at least 4 devices for RAID 6

From
H. Peter Anvin <hpa@zytor.com>
Date
2026-05-14 20:11:10
Also in
linux-arch, linux-arm-kernel, linux-btrfs, linux-crypto, linux-raid, linux-riscv, linux-s390, lkml, loongarch
Reply to
Goffredo Baroncelli, 2026-05-14
On May 14, 2026 12:51:59 PM PDT, Goffredo Baroncelli [off-list ref] wrote:
On 13/05/2026 07.47, Christoph Hellwig wrote:
quoted
On Tue, May 12, 2026 at 01:42:31PM +0200, David Sterba wrote:
quoted
quoted
The degenerate modes of
raid0, 5, or 6 are explicit as a possible middle step when converting
profiles.  We can use a fallback implementation for this case if the
accelerated implementations cannot do it.
This is not about a degenerated mode.  For a degenerated RAID 6, parity
generation uses the RAID 5 XOR routines as the second parity will be
missing.  This is about generating two parities for a single data disk,
which must be explicitly selected.
I think that the David concern is : "what happens for an already
existing btrfs raid6 3 disks filesystem when the user upgrade the kernel ?"
(I am thinking when a new BG needs to be allocated)...

BR
GB
That's what I'm saying – it should invoke the RAID-1 code under the cover (as with 3 disks, D = P = Q.)