Heiko Carstens [off-list ref] writes:
So, the in both variants s390 provides nearly identical data. The only
difference is that for FL_SAVE_REGS the program status word mask is
missing; therefore it is not possible to figure out the condition code
or if interrupts were enabled/disabled.
Vasily, Sven, I think we have two options here:
- don't provide sane psw mask contents at all and say (again) that
ptregs contents are identical
- provide (finally) a full psw mask contents using epsw, and indicate
validity with a flags bit in pt_regs
I would vote for the second option, even though epsw is slow. But this
is about the third or fourth time this came up in different
contexts. So I'd guess we should go for the slow but complete
solution. Opinions?
Given that this only affects ftrace_regs_caller, i would also vote for the
second option.