Thread (3 messages) flat view 3 messages, 3 authors, 2020-08-20

Re: [PATCH v2] powerpc/pseries: Do not initiate shutdown when system is running on UPS

From: Michael Ellerman <hidden>
Date: 2020-08-20 13:31:48
Also in: stable

On Thu, 20 Aug 2020 11:48:44 +0530, Vasant Hegde wrote:
As per PAPR we have to look for both EPOW sensor value and event modifier to
identify type of event and take appropriate action.

Sensor value = 3 (EPOW_SYSTEM_SHUTDOWN) schedule system to be shutdown after
                  OS defined delay (default 10 mins).

EPOW Event Modifier for sensor value = 3:
   We have to initiate immediate shutdown for most of the event modifier except
   value = 2 (system running on UPS).

[...]
Applied to powerpc/fixes.

[1/1] powerpc/pseries: Do not initiate shutdown when system is running on UPS
      https://git.kernel.org/powerpc/c/90a9b102eddf6a3f987d15f4454e26a2532c1c98

cheers