Thread (40 messages) flat view 40 messages, 5 authors, 2019-10-16

Re: [PATCH v5 18/23] powerpc/pci: Handle BAR movement

From: Sergey Miroshnichenko <hidden>
Date: 2019-09-06 16:27:11
Also in: linux-pci

Hi Oliver,

On 9/4/19 8:37 AM, Oliver O'Halloran wrote:
On Fri, 2019-08-16 at 19:50 +0300, Sergey Miroshnichenko wrote:
quoted
Add pcibios_rescan_prepare()/_done() hooks for the powerpc platform. Now if
the device's driver supports movable BARs, pcibios_rescan_prepare() will be
called after the device is stopped, and pcibios_rescan_done() - before it
resumes. There are no memory requests to this device between the hooks, so
it it safe to rebuild the EEH address cache during that.

CC: Oliver O'Halloran <oohall@gmail.com>
Signed-off-by: Sergey Miroshnichenko <redacted>
---
 arch/powerpc/kernel/pci-hotplug.c | 10 ++++++++++
 1 file changed, 10 insertions(+)
diff --git a/arch/powerpc/kernel/pci-hotplug.c b/arch/powerpc/kernel/pci-hotplug.c
index 0b0cf8168b47..18cf13bba228 100644
--- a/arch/powerpc/kernel/pci-hotplug.c
+++ b/arch/powerpc/kernel/pci-hotplug.c
@@ -144,3 +144,13 @@ void pci_hp_add_devices(struct pci_bus *bus)
 	pcibios_finish_adding_to_bus(bus);
 }
 EXPORT_SYMBOL_GPL(pci_hp_add_devices);
+
+void pcibios_rescan_prepare(struct pci_dev *pdev)
+{
+	eeh_addr_cache_rmv_dev(pdev);
+}
+
+void pcibios_rescan_done(struct pci_dev *pdev)
+{
+	eeh_addr_cache_insert_dev(pdev);
+}
Is this actually sufficent? The PE number for a device is largely
determined by the location of the MMIO BARs. If you move a BAR far
enough the PE number stored in the eeh_pe would need to be updated as
well.
Thanks for the hint! I've checked on our PowerNV: for bridges with MEM
only it allocates PE numbers starting from 0xff down, and when there
are MEM64 - starting from 0 up, one PE number per 4GiB.

PEs are allocated during call to pnv_pci_setup_bridge(), and the I've
added invocation of pci_setup_bridge() after a hotplug event in the
"Recalculate all bridge windows during rescan" patch of this series.

Currently, if a bus already has a PE, pnv_ioda_setup_bus_PE() takes it
and returns. I can see two ways to change it, both are not difficult to
implement:

 a.1) check if MEM64 BARs appeared below the bus - allocate and assign
      a new master PE with required number of slave PEs;

 a.2) if the bus now has more MEM64 than before - check if more slave
      PEs must be reserved;

 b) release all the PEs before a PCI rescan and allocate+assign them
    again after - with this approach the "Hook up the writes to
    PCI_SECONDARY_BUS register" patch may be eliminated.

Do you find any of these suitable?

Serge

Attachments

Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help