[PATCH v3 11/21] docs: hwmon: ibmpowernv: convert to ReST format
From: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Date: 2019-04-17 09:47:51
Also in:
linux-doc, linux-hwmon, lkml
Subsystem:
documentation, hardware monitoring, the rest · Maintainers:
Jonathan Corbet, Guenter Roeck, Linus Torvalds
Convert ibmpowernv to ReST format, in order to allow it to be parsed by Sphinx. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> --- Documentation/hwmon/ibmpowernv | 31 +++++++++++++++++++------------ 1 file changed, 19 insertions(+), 12 deletions(-)
diff --git a/Documentation/hwmon/ibmpowernv b/Documentation/hwmon/ibmpowernv
index 56468258711f..5d642bc3dec0 100644
--- a/Documentation/hwmon/ibmpowernv
+++ b/Documentation/hwmon/ibmpowernv@@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV ======================== Supported systems: + * Any recent IBM P servers based on POWERNV platform Author: Neelesh Gupta
@@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. Sysfs attributes ---------------- +======================= ======================================================= fanX_input Measured RPM value. fanX_min Threshold RPM for alert generation. -fanX_fault 0: No fail condition - 1: Failing fan +fanX_fault - 0: No fail condition + - 1: Failing fan tempX_input Measured ambient temperature. tempX_max Threshold ambient temperature for alert generation.
@@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its temperature sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable inX_input Measured power supply voltage (millivolt) -inX_fault 0: No fail condition. - 1: Failing power supply. +inX_fault - 0: No fail condition. + - 1: Failing power supply. inX_highest Historical maximum voltage inX_lowest Historical minimum voltage inX_enable Enable/disable all voltage sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its voltage sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable powerX_input Power consumption (microWatt) powerX_input_highest Historical maximum power
@@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its power sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable currX_input Measured current (milliampere) currX_highest Historical maximum current
@@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its current sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable energyX_input Cumulative energy (microJoule) +======================= =======================================================
--
2.20.1