Re: [PATCH v2 00/15] powerpc/32s: Use BATs/LTLBs for STRICT_KERNEL_RWX

flat view

From: Christophe Leroy <hidden>
Date: 2019-01-15 10:57:45
Also in: lkml


Le 15/01/2019 à 11:22, Michael Ellerman a écrit :
Christophe Leroy [off-list ref] writes:
quoted
Le 15/01/2019 à 01:33, Jonathan Neuschäfer a écrit :
...
quoted
quoted
- patches 7 to 11 fail to build with this error (really a warning, but
    arch/powerpc doesn't allow warnings by default):

	  CC      arch/powerpc/mm/ppc_mmu_32.o
	../arch/powerpc/mm/ppc_mmu_32.c:133:13: error: ‘clearibat’ defined but not used [-Werror=unused-function]
	 static void clearibat(int index)
		     ^~~~~~~~~
	../arch/powerpc/mm/ppc_mmu_32.c:115:13: error: ‘setibat’ defined but not used [-Werror=unused-function]
	 static void setibat(int index, unsigned long virt, phys_addr_t phys,
		     ^~~~~~~
	cc1: all warnings being treated as errors
Argh ! I have to squash the patch bringing the new functions with the
one using them (patch 12). The result is a big messy patch which is more
difficult to review but that's life.
You don't *have* to squash them.

We like to preserve bisectability, but it's not a 100% hard requirement.

Someone trying to bisect through those patches can always turn off
-Werror with PPC_DISABLE_WERROR. But they probably can just skip them
because they just add new code that's not called yet.
Ok thanks for the note.
So I won't object if you send them as-is.
Good to know. Anyway I think I will at least re-order so that the patch using the new functions immediatly follows the one adding the functions.

Christophe
cheers