Thread (11 messages) flat view 11 messages, 4 authors, 2016-10-14

Re: [PATCH 0/6] kvm: powerpc halt polling updates

From: Nicholas Piggin <npiggin@gmail.com>
Date: 2016-10-14 06:27:39
Also in: kvm

On Fri, 14 Oct 2016 11:53:18 +1100
Suraj Jitindar Singh [off-list ref] wrote:
This patch series makes some updates and bug fixes to the powerpc kvm-hv
halt polling code.

The first two patches are concerned with exporting the generic kvm module
parameter variables and accessing these from the powerpc specific code.

The third patch fixes a bug where changing the global max halt polling
interval module parameter can sometimes have no effect.

The fourth patch decreases the default global max halt polling interval
to something more sensible.

The fifth patch contains generic fixups with no functional effect.

The last patch adds halt polling documentation.
I want to enable polling idle in Linux for SPLPAR/KVM as we do for
dedicated mode. Essentially the guest OS will spin for a small time
before ceding.

There will be a lot of interaction between this and halt polling. I
think guest polling may still be worthwhile if you have halt polling in
the host, although it might be less effective. We should set up some
performance testing with various guest/host parameters and see what
works best. What have you been testing with so far?

Thanks,
Nick