RE: [PATCH v2] mtd: m25p80: Make the name of mtd_info fixed
From: B48286@freescale.com <hidden>
Date: 2014-02-13 08:08:39
Also in:
linux-spi
Hi Brian,
-----Original Message----- From: Brian Norris [mailto:computersforpeace@gmail.com] Sent: Tuesday, February 11, 2014 3:40 AM To: Hou Zhiqiang-B48286 Cc: linux-mtd@lists.infradead.org; linuxppc-dev@ozlabs.org; Wood Scott- B07421; Hu Mingkai-B21284; linux-spi@vger.kernel.org Subject: Re: [PATCH v2] mtd: m25p80: Make the name of mtd_info fixed =20 On Sun, Jan 26, 2014 at 02:16:43PM +0800, Hou Zhiqiang wrote:quoted
To give spi flash layout using "mtdparts=3D..." in cmdline, we must giv=
e
quoted
mtd_info a fixed name,because the cmdlinepart's parser will match the name given in cmdline with the mtd_info. Now, if use OF node, mtd_info's name will be spi->dev->name. It consists of spi_master->bus_num, and the spi_master->bus_num maybe dynamically fetched. So, give the mtd_info a new fiexd name "name.cs", "name" is name of spi_device_id and "cs" is chip-select in spi_dev. Signed-off-by: Hou Zhiqiang <redacted> --- v2: - add check for return value of function kasprintf. - whether the spi_master->bus_num is dynamical is determined by spi controller driver, and it can't be check in this driver. So, we can not initial the mtd_info's name by distinguishing the spi_master bus_num dynamically-allocated or not.=20 How about spi->master->bus_num < 0 ? =20
In spi slave driver, we can not see this case. The spi->master->bus_num=20 must be greater than 0, because before loading spi slave driver, the spi controller driver will check spi->master->bus_num, if it is less than 0, the spi controller driver will allocate a new bus_num dynamically. So it is always greater than 0 in m25p80.c.
quoted
drivers/mtd/devices/m25p80.c | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-)diff --git a/drivers/mtd/devices/m25p80.cb/drivers/mtd/devices/m25p80.c index eb558e8..1f494d2 100644--- a/drivers/mtd/devices/m25p80.c +++ b/drivers/mtd/devices/m25p80.c@@ -1011,8 +1011,12 @@ static int m25p_probe(struct spi_device *spi) if (data && data->name) flash->mtd.name =3D data->name; - else - flash->mtd.name =3D dev_name(&spi->dev); + else { + flash->mtd.name =3D kasprintf(GFP_KERNEL, "%s.%d", + id->name, spi->chip_select);=20 I don't think this name is specific enough. What if there are more than one SPI controller? Then there could be one chip with the same chip- select. You probably still need to incorporate the SPI master somehow, even if it's not by using the bus number directly (because it's dynamic).
Yeah, you're right. Actually the bus_num is used to distinguish different spi controller. If the controller driver give a dynamically-allocated bus_num, yourself should take the risk to use mtdparts in command line. I think, it is spi controller driver's responsibility to assign a reasonable bus_num to make sure using command line mtdparts riskless, then it is unnecessary to change mtdinfo's name. =20
quoted
+ if (!flash->mtd.name) + return -ENOMEM; + } flash->mtd.type =3D MTD_NORFLASH; flash->mtd.writesize =3D 1;=20 Brian =20
Zhiqiang Hou