slots-fan on G5 Xserve is always running at full speed with windfarm_rm31
driver, resulting in a very high acoustic noise level. It seems the fan
parameters are incorrect, and have been copied from the Drive Bay fan
(RPM, not present on rm31) of the legacy therm_pm72 driver. This patch
changes the parameters to match the Slots fan (PWM) of therm_pm72. With
the patch, slots-fan speed drops from 99% to 19% during normal use,
and slots-temp settle to ~42'C.
Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi>
---
drivers/macintosh/windfarm_rm31.c | 18 +++++++++---------
1 file changed, 9 insertions(+), 9 deletions(-)
diff --git a/drivers/macintosh/windfarm_rm31.c b/drivers/macintosh/windfarm_rm31.c
index 0b9a79b..82fc86a 100644
--- a/drivers/macintosh/windfarm_rm31.c
+++ b/drivers/macintosh/windfarm_rm31.c@@ -439,15 +439,15 @@ static void backside_setup_pid(void) /* Slots fan */ static const struct wf_pid_param slots_param = { - .interval = 5, - .history_len = 2, - .gd = 30 << 20, - .gp = 5 << 20, - .gr = 0, - .itarget = 40 << 16, - .additive = 1, - .min = 300, - .max = 4000, + .interval = 1, + .history_len = 20, + .gd = 0, + .gp = 0, + .gr = 0x00100000, + .itarget = 3200000, + .additive = 0, + .min = 20, + .max = 100, }; static void slots_fan_tick(void)
--
1.8.3.2