On Fri, 2011-11-18 at 10:33 +0530, Prashant Bhole wrote:
Hi,
I have been facing problem with ibm_newemac driver (v3.54).
The board gets disconnected and can not be pinged in between
some heavy network traffic. In my case I am running IOmeter
"All-in-One" 8 threads on the iSCSI target. MTU is 4088.
I found that after executing emac_full_tx_reset(), the board can
be pinged again. Again after some heavy traffic of 5-6 seconds,
traffic stops. This can be repeated after full tx reset.
Is this a known issue? what could cause this?
Any pointers would be greatly appreciated.
Not that I know of. Can you check if any of the error reporting
registers trip anything ? Could it just be a fifo overflow which we may
not be handling properly in the driver ?
Cheers,
Ben.