Thread (5 messages) flat view 5 messages, 3 authors, 2007-08-10

Re: [PATCH 1/2] pseries: device node status can be "ok" or "okay"

From: Matt Sealey <hidden>
Date: 2007-08-10 19:22:13

Segher Boessenkool wrote:
quoted
It seems that some versions of firmware will report a device
node status as the string "okay". As we are not expecting this
string, the device node will be ignored by the EEH subsystem.
Which means EEH will not be enabled.

When EEH is not enabled, PCI errors will be converted into
Machine Check exceptions, and we'll have a very unhappy system.
quoted
-	if (status && strcmp(status, "ok") != 0)
+	if (status && strncmp(status, "ok", 2) != 0)
 		return NULL;	/* ignore devices with bad status */
Shouldn't you check for the two literal strings, instead of
only matching the common prefix?  Seems safer.
What are the chances that the status string is "oklahoma" or
"okeechobee" or "okinawa"?

-- 
Matt Sealey [off-list ref]
Genesi, Manager, Developer Relations