Re: [PATCH]Enabling Auto poweron after power is restored.
From: Paul Mackerras <hidden>
Date: 2006-12-08 06:09:35
From: Paul Mackerras <hidden>
Date: 2006-12-08 06:09:35
Manish Ahuja writes:
During power outages, the ups notifies the system for a shutdown. In the current setup, it isn't possible to power on when power is restored. This patch fixes the issue by calling the right ibm,power-off-ups token during such events. It also adds a proc interface so that rc.powerfail can parse the epow events and modify the power-off behavior accordingly to enable the right token to be called.
With this patch, the kernel won't build if CONFIG_PPC_RTAS=y and CONFIG_RTAS_PROC=n. Please move the definition of rtas_poweron_auto from rtas-proc.c to rtas.c so that this (admittedly somewhat strange) config will build. Thanks, Paul.