El sáb, 11-02-2006 a las 16:28 +0100, Sylvain Munaut escribió:
Asier Llano Palacios wrote:
Did you ever observe that behavior on a lite5200 ?
What is 'long uptime' and do you have sustained transfer during that
period ? (To try reproduice the problem).
Weeks uptime. We don't work with the lite5200 for so long time, but our
board is based on a lite5200, and the FEC configuration is exactly
equal.
Also, what are the 'symptoms' ? (anything in dmesg ?)
FEC doesn't work at all, everything else works. If using a console I
execute 'ifconfig eth0 down && ifconfig eth0 up <IP>' the fec starts
working again.
I haven't reproduced it directly, but a partner and a customer. I'll try
to reproduce this behaviour myself and bring back more information.
I haven't touched the FEC code much except to remove the
aligment code (newer bestcomm microcode doesn't require alignement of
the skb).
You can send me the driver/net/fec_mpc52xx and arch/ppc/syslib/bestcomm
you're using, I'll tell you if there was major changes.
I've sent to you the patches that I extracted from your kernel source
tree some time ago.
I have all the patches until the 1.2161 one. But I've only sent to you
the ones related to the FEC and the bestcomm.
--
Asier Llano Palacios
ZIV I+D Smart Energy Networks
Dpto. Ingeniería de Desarrollo.
ZIV, Aplicaciones y Tecnología.
Parque Tecnológico, 210
48170 ZAMUDIO (Bizkaia)
E-mail: a.llano@ziv.es
Tlfno: 944037400
----------------------------------------- PLEASE NOTE -------------------------------------------
This message, along with any attachments, may be confidential or legally privileged.
It is intended only for the named person(s), who is/are the only authorized recipients.
If this message has reached you in error, kindly destroy it without review and notify the sender immediately.
Thank you for your help.
µSysCom uses virus scanning software but excludes any liability for viruses contained in any attachment.
------------------------------------ ROGAMOS LEA ESTE TEXTO -------------------------------
Este mensaje y sus anexos pueden contener información confidencial y/o con derecho legal.
Está dirigido únicamente a la/s persona/s o entidad/es reseñadas como único destinatario autorizado.
Si este mensaje le hubiera llegado por error, por favor elimínelo sin revisarlo ni reenviarlo y notifíquelo inmediatamente al remitente. Gracias por su colaboración.
µSysCom utiliza software antivirus, pero no se hace responsable de los virus contenidos en los ficheros anexos.