Hi Allann,
out_8(&psc->command, MPC5xxx_PSC_RST_RX |
MPC5xxx_PSC_RST_TX |
MPC5xxx_PSC_SEL_MODE_REG_1 |
MPC5xxx_PSC_RST_ERR_STAT);
It looks like you're trying to do too many things at once here. =20
ORing SEL_MODE_REG_1 and RST_ERR_STAT together=20
forms a completely different command in the Command=20
register. You may want to break that into two lines of code. =20
Give that a try!
Open Systems International, Inc.=20
Nathan Zeitler
Hardware Engineer
3600 Holly Lane North, Suite 40
Minneapolis, MN 55447-1286
Phone: 763 551 0559
Fax: 763 551 0750
E-mail: nzeitler@osii.com