Thread (2 messages) flat view 2 messages, 2 authors, 2004-11-05

Re: Handling power failure - MPC5200

From: Jón Benediktsson <hidden>
Date: 2004-11-05 14:13:23

In message <OF368071C2.FBC6B7BC-ON00256F42.003F3DF3-00256F42.
0044E8BB@marel.is> you wrote:
quoted
=20
Capacitors on the supply provide me with some milliseconds to repond=20
to=20
quoted
power failure, which I would
like to use to do as much cleanup as possible before power is totally=20
gone.  In particular, I am concerned
=20
How many is "some"? If it's not >100 or so it is probably  not  worht
the effort...
With the current design "some" is <50, but we can change the design if
we find it necessary.
=20
=20
Use the standard methods: use the CF card read-only  (many  CF  cards
can  be  damaged  [beyond  repair]  when  you power off while a write
operation is in progress).
Is this an acknowledged fact by CF manufacturers or based on experiece ?

Thank you very much for your input.

Regards,
J=F3n Benediktsson
Marel hf.