Re: ppcboot boot-up question
From: Wolfgang Denk <hidden>
Date: 2004-02-02 22:26:12
In message [ref] you wrote:
I'm using PPCBoot 2.0.0
... which is ancient.
I have my PPC 750 setup to delay for 5sec then boot from the DiskOnChip. This works properly, as long as I have an active serial connection to the board. However, I've noticed that if there is not an active serial connection to the board, the autoboot function will not work. If I reset the board, with no serial connection, then start minicom after 10 seconds I always find the following: => AT S7=45 S0=0 L1 V1 X4 &c1 E1 Q0 syntax error
It seems you configured miniom to send a modem init string. This is not expected by PPCBoot.
Does anyone know what I am doing wrong??
You use minicom.
You post to the wrong list (u-boot-users is a much better place for
such questions).
You don't provide any details. Maybe the serial driver on your board
is waiting for a hardware handshake signal (DCD?) which is down while
disconnected? What happens when you disconnect the cable?
Best regards,
Wolfgang Denk
--
See us @ Embedded World, Nuremberg, Feb 17 - 19, Hall 12.0 Booth 440
Phone: (+49)-8142-4596-87 Fax: (+49)-8142-4596-88 Email: wd@denx.de
I see that Microsoft's campaign to destroy all knowledge of any
operating environment but its own environment-of-the-year has
succeeded in creating a generation of users who don't understand the
concept of a shell...
-- L. Peter Deutsch in [off-list ref]