RE: running 8xx without UART
From: Stephan Linke <hidden>
Date: 2003-06-13 06:52:00
Hi, there appeares to be a microcode patch for MPC862 that allowes relocating SMC, SPI and I2C Parameter RAM. This should help getting SMC1 running while SCC3 is doing Ethernet. Thanks, Stephan
-----Original Message----- From: <redacted> [mailto:owner-linuxppc-embedded@lists.linuxppc.org]On Behalf Of Stephan Linke Sent: Donnerstag, 12. Juni 2003 13:43 To: <redacted> Cc: Linuxppc-Embedded Subject: RE: running 8xx without UART Hi,quoted
-----Original Message----- From: <redacted> [mailto:<redacted>] Sent: Donnerstag, 12. Juni 2003 13:22 To: Stephan Linke Subject: Re: running 8xx without UART In message [off-list ref] you wrote:quoted
Sorry, I accidentialy replied to the wrong mail...Kein Problem :-)quoted
this problem is actualy no kernel bug. It is a limitation of the 862 family that you can't use SMC1 while you useSCC3 as ATM orquoted
quoted
ethernet. It's not so well documented. Thant's why we run into that trap. The special problem on 852 is that there areony 2 SCC'squoted
and 1 SMC. :-)...quoted
quoted
quoted
We are experiencing problems with SCC3 running ethernet and SMC1 as console interface on a 852.SCC3 = Ethernet or SCC3 = ATM?We are using SCC3 as ethernet (Actualy there is no ATM on MPC852. But I guess that doesn't make a difference). :-) Stephan
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/