Re: BDI2000 and 405GPr
From: Peter Vandenabeele <hidden>
Date: 2002-12-31 02:38:23
On Mon, Dec 30, 2002 at 08:21:53PM -0800, Jerry Walden wrote:
Hello: I just got my re-spun 405GPr based SBC from our board manufacturer. I'm not certain if this is the proper place to ask this question, if not perhaps you can direct me to another source.
Well, if you ask support to Abatron through your local supplier, they will typically give very good support.
I just purchased the latest and greated BDI2000, and when I telnet to the emulator I get the following over and over.... BDI> - TARGET: processing user reset request *** TARGET: reseting target failed # JTAG: Communication test failed - TARGET: target will be restarted in 10 sec BDI> - TARGET: processing user reset request *** TARGET: reseting target failed # JTAG: Communication test failed - TARGET: target will be restarted in 10 sec
It is normal behavior for the BDI 2000 to try again after a failed set-up every 10 seconds. How is your reset exactly connected (electrically). You have 2 reset lines (one CPU RESET and one general RESET). They are triggered in a specific order by the BDI for the 405GP. Are they connected correctly to the logic of your board ? Are there any reset chips that prolongue the global reset ? (I believe the max time in the standard version should be not more than 500 msec). Do you see any signal on TDO ? Peter
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/