In message <B25E2E5A003CD311B61E00902778AF2A0204433C@SERVER1> you wrote:
Is anyone out there using the Abatron BDI2000 to set hardware breakpoints on
data access (on 405GP)? I'm probably just doing something dumb, but I don't
see it. Any ideas?
Not on 405, but on 8xx / 82xx instead.
BDI>bd w 0xc019c390
# syntax is BDx [R|W]
BDI>bd w 0xc019c390
Breakpoint identification is 0

Works fine for me.
BDI>bdx w 0xc019c390
# syntax error in command
Error, "bdx" is no valid command.
BDI>bd w c019c390
# syntax error in command
Error, c0... is no valid hex number (0x... missing).
BDI>bd 0xc019c390
# syntax is BDx [R|W]
BDI>bd 0xc019c390
Breakpoint identification is 1

Works fine for me.

Um... Try re-loading the firmware.