Re: pmud monitoring temperature (Re: powerbook doubles)
flat view
From: Troy Benjegerdes <hidden>
Date: 2001-01-29 22:24:25
On Mon, Jan 29, 2001 at 03:49:02PM +0100, Michael Schmitz wrote:
quoted
i reworked this patch to work with the current bk tree (argh. i just complained to iain that diffs against a moving target were gross) http://redcloud.uccs.edu/~bcmidgle/linux/ btw, it looks like troy wants the _{gs}et_THRM{123} macros changed to use some different macros, but i'm not familiar with that stuff so i just reenabled the old macros.I don't think what changes you propose there but from the comment on your patch page ('cpu speed not included in calculations') it seems you picked up the old version of the patch. I attach the version including conversion time calculation from processor speed (for 2.4.0pre). The CPU speed is preset to 500 MHz in case it can't be determined from OF, this gives too long conversion times for slower processors - does this hurt? What is the maximum CPU speed for machines without clock_frequency present in the device tree?
Guys, you should *really* take a look at the CONFIG_TAU stuff in linuxppc_2_5. It's interrupt driven, so the delay doesn't really matter, and you can't cause a DOS by infinitely re-reading /proc/cpuinfo. And does anyone think this is tested enough to move to linuxppc_2_4? -------------------------------------------------------------------------- Troy Benjegerdes 'da hozer' hozer@drgw.net ** Sent via the linuxppc-dev mail list. See http://lists.linuxppc.org/