Thread (5 messages) flat view 5 messages, 3 authors, 2000-03-24

Re: Synchronous SCSI at 10MB/s on Lombard? (fwd)

From: Joseph Garcia <hidden>
Date: 2000-03-23 18:08:31

Derek Homeier wrote:
Has anyone tried to set the rate for synchronous SCSI tranfer for the MESH
controller in the G3 series Powerbooks to 10? The kernel docs claim it does
10 MB/sec on machines where the bus is internal only:
I have tried it on my PDQ/300.  My SyQuest worked fine, but according to /proc,
it was still running at 5.  however, my yamaha cdrw did not work.  set 5, it
reports its sync speed is 4.2.  when MESH is told to max at 10, my RW is still
recognized, reports 8.4, but does not respond to mounting, reading, nor
writing.  It could be that the 6.6 you have achieved is still doable, but my 8.4
is not. so setting MESH to 7 or 8 may be a safer fast speed.  havent tried it
though.

--
Joseph P. Garcia      jpgarcia@execpc.com      jpgarcia@lidar.ssec.wisc.edu