Thread (4 messages) flat view 4 messages, 4 authors, 1999-10-14

Re: serial on lombard

From: Michael Schmitz <hidden>
Date: 1999-10-14 11:19:17

quoted hunk ↗ jump to hunk
alarm(0x2, 0x7ffff7b4, 0, 0x8, 0x7f7f7f7f) = 0
open("/dev/ttyS0", O_RDWR|O_NONBLOCK)   = 3
--- SIGALRM (Alarm clock) ---
alarm(0, 0x1, 0, 0x8, 0x7f7f7f7f)       = 0
rt_sigaction(0xe, 0x7ffff698, 0x7ffff728, 0x8) = 0
write(2, "minicom: cannot open /dev/ttyS0:"..., 59minicom: cannot open /dev/ttyS0: No such file or directory
) = 59
The port blocks on open, and you get a timeout. 

The serial port won't open without carrier detected. minicom fails to set
the port characteristics properly (or the Mac serial driver doesn't honor
minicom's port settings), and gives a very confusing error message (open
/dev/ttyS0 timed out would have been more accurate). 

Set ttyS0 to ignore DCD with stty clocal </dev/ttyS0, perhaps.

	Michael