From: Ulrich Huber <hidden>
Date: 2021-08-26 19:51:03

On 26.08.21 16:25, Heikki Krogerus wrote:
On Wed, Aug 25, 2021 at 08:37:14PM +0200, Ulrich Huber wrote:  >> Hi, >> >> I just managed to get some more details. The bug definitely originates from >> `ucsi_handle_connector_change`. Within this function it is the second call >> to ucsi_send_command with UCSI_GET_CONNECTOR_STATUS that fails (Step 4). >> >> `ucsi_send_command` calls `ucsi_exec_command` internally, which does the >> synchronous write and following read. Within `ucsi_exec_command` the check >> on line 134 fails: >> >> if (cci & UCSI_CCI_COMMAND_COMPLETE) >> >> Hope this is of some help. > Thanks for debugging this.
You are welcome!
Yeah, I think that the second GET_CONNECTOR_STATUS immediately after  > the first one is confusing the firmware on some board> > I'll send you a patch series I've been working on that tries to > improve the situation. I better include the list as well (sending it > as RFC).
I just got around to test your patches. They seem to solve the issue completely! Whatever I tried, the behavior of the port stayed consistent and no error messages appeared in the log.

I'll continue using the patch for now and will notify you, should any issue appear.

Thanks
Ulrich