On 17-08-21, 18:49, Dmitry Osipenko wrote:
17.08.2021 10:55, Viresh Kumar пишет:
...
quoted
quoted
+int dev_pm_opp_sync(struct device *dev)
+{
+ struct opp_table *opp_table;
+ struct dev_pm_opp *opp;
+ int ret = 0;
+
+ /* Device may not have OPP table */
+ opp_table = _find_opp_table(dev);
+ if (IS_ERR(opp_table))
+ return 0;
+
+ if (!_get_opp_count(opp_table))
+ goto put_table;
+
+ opp = _find_current_opp(dev, opp_table);
+ ret = _set_opp(dev, opp_table, opp, opp->rate);
And I am not sure how this will end up working, since new OPP will be
equal to old one. Since I see you call this from resume() at many
places.
Initially OPP table is "uninitialized" and opp_table->enabled=false,
hence the first sync always works even if OPP is equal to old one. Once
OPP has been synced, all further syncs are NO-OPs, hence it doesn't
matter how many times syncing is called.
https://elixir.bootlin.com/linux/v5.14-rc6/source/drivers/opp/core.c#L1012
Right, but how will this work from Resume ? Won't that be a no-op ?
--
viresh