Re: pl2303.c 110 baud not working

From
Joe Abbott <hidden>
Date
2021-01-30 11:31:22
 Sorry it's been so long.  Busy.
 >
 > So in any case, we'd need to key this off of the device type.
 >
 Yes, key off type as I can't find the relationship.  Windows
 uses a8 a6 01 80 02 07  for any request near 110  and switches
 to direct encode for anything near 75 or 150.

 > I noticed that
 >
 >         12000000 / 0x1a6a8 ~= 110.9
 >
 > Possibly just a coincidence, especially as 0x1aa22 would be closer
 > match. But perhaps you can try a few more rates not in baud_sup and see
 > if you can figure it out.

 Coincidence. 0x01aa22 doesn't work. Not even close.

 I had to give up.  Too many other things to do and hard coding
 is working for me.

 Thanks for your help anyway.

 Joe