tools/rv: Stop gracefully also on SIGTERM

Started by Gabriele Monaco on Jul 15, 2025

Subsystems (2)

Maintainers (3)

DORMANTno replies SUPERSEDED

Status: Superseded by v5 (posted 2025-07-28). [go to v5]

Revision v3 (5 revisions archived).

Revisions (5)
  1. rfc
  2. v2 [diff against previous]
  3. v3 current [diff against previous]
  4. v4 [diff against previous]
  5. v5 [diff against previous]

open the first message on its own page

Message details and related content
Currently the userspace RV tool starts a monitor and waits for the user
to press Ctrl-C (SIGINT) to terminate and stop the monitor.
This doesn't account for a scenario where a user starts RV in background
and simply kills it (SIGTERM unless the user specifies differently).
E.g.:
 # rv mon wip &
 # kill %

Would terminate RV without stopping the monitor and next RV executions
won't start correctly.

Register the signal handler used for SIGINT also to SIGTERM.

Signed-off-by: Gabriele Monaco <gmonaco@redhat.com>
---
 tools/verification/rv/src/rv.c | 1 +
 1 file changed, 1 insertion(+)
diff --git a/tools/verification/rv/src/rv.c b/tools/verification/rv/src/rv.c
index 239de054d1e06..b8fe24a87d97c 100644
--- a/tools/verification/rv/src/rv.c
+++ b/tools/verification/rv/src/rv.c
@@ -191,6 +191,7 @@ int main(int argc, char **argv)
 		 * and exit.
 		 */
 		signal(SIGINT, stop_rv);
+		signal(SIGTERM, stop_rv);
 
 		rv_mon(argc - 1, &argv[1]);
 	}
-- 
2.50.1