When rs485 transmission over an 8250 port stops, __stop_tx() assigns
active_timer = NULL before calling __stop_tx_rs485().
That function in turn either assigns active_timer = stop_tx_timer and
rearms the timer (in case a delay_rts_after_send needs to be observed)
or directly calls __do_stop_tx_rs485().
Move the assignment active_timer = NULL to __stop_tx_rs485() into the
branch which directly calls __do_stop_tx_rs485(), thereby avoiding a
duplicate assignment and simplifying the code.
Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: Matwey V. Kornilov <redacted>
---
drivers/tty/serial/8250/8250_port.c | 3 +--
1 file changed, 1 insertion(+), 2 deletions(-)
diff --git a/drivers/tty/serial/8250/8250_port.c b/drivers/tty/serial/8250/8250_port.c
index d281aea061d6..1a71625a0d43 100644
--- a/drivers/tty/serial/8250/8250_port.c
+++ b/drivers/tty/serial/8250/8250_port.c
@@ -1498,6 +1498,7 @@ static void __stop_tx_rs485(struct uart_8250_port *p)
p->port.rs485.delay_rts_after_send);
} else {
__do_stop_tx_rs485(p);
+ em485->active_timer = NULL;
}
}
@@ -1522,8 +1523,6 @@ static inline void __stop_tx(struct uart_8250_port *p)
if ((lsr & BOTH_EMPTY) != BOTH_EMPTY)
return;
- em485->active_timer = NULL;
-
__stop_tx_rs485(p);
}
__do_stop_tx(p);
--
2.24.0