Thread (12 messages) 12 messages, 2 authors, 2013-09-12

Re: commit 5fe212364 causes division by zero with large bauds

From: Alexey Pelykh <hidden>
Date: 2013-09-11 18:48:36
Also in: linux-omap, lkml

On Wed, Sep 11, 2013 at 9:38 PM, Felipe Balbi [off-list ref] wrote:
Hi,

On Wed, Sep 11, 2013 at 09:22:26AM +0300, Alexey Pelykh wrote:
quoted
Hi Felipe,

Thanks for finding this issue. Indeed, there is a bug on 3M+ baud
rates. First patch is close to a complete fix, but still contains
div-by-zero issue. Here is my version:
diff --git a/drivers/tty/serial/omap-serial.c b/drivers/tty/serial/omap-serial.c
index 816d1a2..808a880 100644
--- a/drivers/tty/serial/omap-serial.c
+++ b/drivers/tty/serial/omap-serial.c
@@ -240,8 +240,8 @@ serial_omap_baud_is_mode16(struct uart_port *port,
unsigned int baud)
 {
        unsigned int n13 = port->uartclk / (13 * baud);
        unsigned int n16 = port->uartclk / (16 * baud);
-       int baudAbsDiff13 = baud - (port->uartclk / (13 * n13));
-       int baudAbsDiff16 = baud - (port->uartclk / (16 * n16));
+       int baudAbsDiff13 = n13 ? (baud - (port->uartclk / (13 * n13))) : INT_MAX;
+       int baudAbsDiff16 = n16 ? (baud - (port->uartclk / (16 * n16))) : INT_MAX;
IOW:

int baudAbsDiff13 = 0;

if (n13)
        baudAbsDiff13 = (baud - (port->uartclk / (13 * n13)));
Not quite same code, INT_MAX instead of 0. With 0 a div-by-zero
exception will still occur on 3686400.
which is exactly what my patch did. I fail to see where division by zero
would be coming from.
quoted
        if(baudAbsDiff13 < 0)
                baudAbsDiff13 = -baudAbsDiff13;
        if(baudAbsDiff16 < 0)


With 48MHz UART clock, it will give
300: divisor = 12307 (13), real rate 300 (0.000000%)
600: divisor = 6153 (13), real rate 600 (0.000000%)
1200: divisor = 3076 (13), real rate 1200 (0.000000%)
2400: divisor = 1538 (13), real rate 2400 (0.000000%)
TRM has these all set with oversampling of 16. In fact only 460800,
921600, 1843200 and 3686400 should be using oversampling of 13.
That's true, but TRM anyways does not contain all possible baud rates
(1M e.g.). IMO, as long as error rate is the same as in TRM,
it makes no difference what combination of (mode, divisor) to use.
--
balbi
A complex solution may be implemented: use LUT for baud rates that TRM
defines explicitly, and use calculation if lookup failed.

Thanks,
Alexey
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help