Thread (42 messages) 42 messages, 4 authors, 2021-09-28

RE: [PATCH v3 09/17] scsi: ufs: ufs-exynos: correct timeout value setting registers

From: Chanho Park <hidden>
Date: 2021-09-23 05:47:52
Also in: linux-samsung-soc

quoted
Subject: [PATCH v3 09/17] scsi: ufs: ufs-exynos: correct timeout value
setting registers

PA_PWRMODEUSERDATA0 -> DL_FC0PROTTIMEOUTVAL
PA_PWRMODEUSERDATA1 -> DL_TC0REPLAYTIMEOUTVAL
PA_PWRMODEUSERDATA2 -> DL_AFC0REQTIMEOUTVAL

Cc: Alim Akhtar <alim.akhtar@samsung.com>
Cc: Kiwoong Kim <redacted>
Cc: Krzysztof Kozlowski <redacted>
Signed-off-by: Chanho Park <redacted>
---
Please add a [Fixes] tag with the original commit which introduce this
I'll add below "Fixes" tag.

Fixes: a967ddb22d94 ("scsi: ufs: ufs-exynos: Apply vendor-specific values for three timeouts")
With the above fix, feel free to add

Reviewed-by: Alim Akhtar <alim.akhtar@samsung.com>
Thanks for your review :)

Best Regards,
Chanho Park