RE: [PATCH v3 09/17] scsi: ufs: ufs-exynos: correct timeout value setting registers
From: Chanho Park <hidden>
Date: 2021-09-23 05:47:52
Also in:
linux-samsung-soc
From: Chanho Park <hidden>
Date: 2021-09-23 05:47:52
Also in:
linux-samsung-soc
quoted
Subject: [PATCH v3 09/17] scsi: ufs: ufs-exynos: correct timeout value setting registers PA_PWRMODEUSERDATA0 -> DL_FC0PROTTIMEOUTVAL PA_PWRMODEUSERDATA1 -> DL_TC0REPLAYTIMEOUTVAL PA_PWRMODEUSERDATA2 -> DL_AFC0REQTIMEOUTVAL Cc: Alim Akhtar <alim.akhtar@samsung.com> Cc: Kiwoong Kim <redacted> Cc: Krzysztof Kozlowski <redacted> Signed-off-by: Chanho Park <redacted> ---Please add a [Fixes] tag with the original commit which introduce this
I'll add below "Fixes" tag.
Fixes: a967ddb22d94 ("scsi: ufs: ufs-exynos: Apply vendor-specific values for three timeouts")
With the above fix, feel free to add Reviewed-by: Alim Akhtar <alim.akhtar@samsung.com>
Thanks for your review :) Best Regards, Chanho Park