[rtc-linux] [PATCH v2 0/5] rtc: s35390a: allow shutdown of NAS after alarm triggered
From: Uwe Kleine-König <hidden>
Date: 2016-07-02 15:28:18
Hello, this is v2 of the series fixing https://bugs.debian.org/794266. The only change compared to (implicit) v1 is that reading out a disabled alarm is fixed. When the alarm is disabled the respective register is shadowed with the result is that the reported alarm time is 45:85:0 because both hour and minute byte are read as 0xff and bcd2bin(0x3f) and bcd2bin(0x7f) are 45 and 85 respectively. The new behaviour is to only set .enabled =3D 0 and return. Not 100% sure this is the right thing, though. The only alternative is to enable alarm and read out a time, but that might have the side effect to trigger an unwanted alarm, so I didn't chose this way. Best regards Uwe Uwe Kleine-K=C3=B6nig (5): rtc: s35390a: fix reading out alarm rtc: s35390a: implement reset routine as suggested by the reference rtc: s35390a: improve irq handling rtc: s35390a: improve two comments in .set_alarm rtc: fix a typo and reduce three empty lines to one drivers/rtc/interface.c | 4 +- drivers/rtc/rtc-s35390a.c | 157 +++++++++++++++++++++++++++++++++++-------= ---- 2 files changed, 120 insertions(+), 41 deletions(-) --=20 2.8.1 --=20 You received this message because you are subscribed to "rtc-linux". Membership options at http://groups.google.com/group/rtc-linux . Please read http://groups.google.com/group/rtc-linux/web/checklist before submitting a driver. ---=20 You received this message because you are subscribed to the Google Groups "= rtc-linux" group. To unsubscribe from this group and stop receiving emails from it, send an e= mail to rtc-linux+unsubscribe@googlegroups.com. For more options, visit https://groups.google.com/d/optout.