Il giorno dom 11 set 2022 alle ore 12:52 Reindl Harald
[off-list ref] ha scritto:
just throw it out of the array - on a RAID 1 with two disk you have
still redundancy and i won't trust a disk which recognized that it has
errors on it's own
Why ? if it's just a single sector, the rest of the disk could be used
properly until the replacement.
what's the point of "can i delay" when you have no other options? :-)
The option is: i've ordered the new disk, it should arrive this thursday.
If i'm still on the safe side, i'll wait, if not, i'll replace with
the first disk I have here, even if slower