On 8/30/21 4:25 AM, Mateusz Grzonka wrote:
Change inappropriate error message "at least 2 raid-devices needed for
level 4 or 5" to only mention relevant raid level.
Signed-off-by: Mateusz Grzonka <redacted>
Looks good, applied!
Thanks,
Jes
quoted hunk ↗ jump to hunk
---
Create.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/Create.c b/Create.c
index f5d57f8c..2c0b17e9 100644
--- a/Create.c
+++ b/Create.c
@@ -153,7 +153,7 @@ int Create(struct supertype *st, char *mddev,
return 1;
}
if (s->raiddisks < 2 && s->level >= 4) {
- pr_err("at least 2 raid-devices needed for level 4 or 5\n");
+ pr_err("at least 2 raid-devices needed for level %d\n", s->level);
return 1;
}
if (s->level <= 0 && s->sparedisks) {