Thread (8 messages) 8 messages, 4 authors, 2022-01-15

Re: mdadm resync causes stable system to crash every 2 or 3 hours

From: Ryan Patterson <hidden>
Date: 2021-09-07 22:38:59

On Tue, Sep 7, 2021 at 1:01 AM Wols Lists [off-list ref] wrote:
On 07/09/21 01:44, Ryan Patterson wrote:
quoted
My file server is usually very stable.  The past week I had two mdadm
arrays that required recync operations.
* newly created raid6 array (14 x 16TB seagate exos)
* existing raid 6 array, after a reboot resync on hot spare (14 x 4TB
seagate barracuda)
Aaarghhh

See
https://raid.wiki.kernel.org/index.php/Linux_Raid

And especially
https://raid.wiki.kernel.org/index.php/Timeout_Mismatch

That might not be your problem, but it's the very first thing you should
address!

Cheers,
Wol
Thanks for the links.  I'm confident my issue is not Timeout Mismatch
related.  I've experienced that before.  It manifested with different
symptoms.  ie. mdadm would think a disk had failed and remove it from
the array.  But the system/OS stayed stable the whole time.

The seagate exos drives support SCT Error Recovery Control and it is
set correctly.  The barracuda drives do not support it, but I've used
these drives for six or seven years without issue.

-Ryan
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help