Thread (4 messages) 4 messages, 3 authors, 2020-01-13

Re: Reassembling Raid5 in degraded state

From: Wol <hidden>
Date: 2020-01-13 18:46:40

On 13/01/2020 17:31, Song Liu wrote:
quoted
Song, Neil,

Just a guess as to what went wrong, but the array event count does not
match the disk counts. Iirc this is one of the events that cause an
Which mismatch do you mean?
quoted
assemble to stop. Is it possible that a crash at the wrong moment could
interrupt an update and trigger this problem?
It looks like sdc1 failed first. Then sdd1 and sdf1 got events for sdc1 failed.
Based on super block on sdd1 and sdf1, we already have two failed drive,
so assemble stopped.

Does this answer the question?
Sorry yes it does. My fault for mis-reading the logs the OP sent.

Cheers.,
Wol
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help