Thread (3 messages) 3 messages, 3 authors, 2017-11-01

Re: [PATCH] Monitor: Allow taking spare from rebuilding array

From: Erik Berg <hidden>
Date: 2017-10-31 11:23:45

On 10/25/2017 10:37 AM, Erik Berg wrote:
When you have a box with 60 8TB drives, 8 RAID6 sets and 12 spares
assigned to the first set, and the first set has a failed disk and is
rebuilding, spares aren't given to other sets with failing disks.
Waiting 2-3 days for a rebuild to complete before giving out spares to
other failing sets seems excessive.
Anyone got any comments/opinions on this, or suggestions as to other 
ways of doing this?

We'd ultimately just like to have a pool of 12 spares that can go to any 
raid-set as drives fail.


--
erikberg
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help