J Jes Sorensen #
Message details and related content
Mariusz Dabrowski [off-list ref] writes:
mdadm recognizes devices with partition table as part of an RAID array and invalid warning message is displayed. After this fix proper warning messages are being displayed for MBR/GPT disks and devices with RAID metadata.
A couple of issues here - in general please respect proper coding
style. This patch is a mess :(
quoted hunk
Signed-off-by: Mariusz Dabrowski <redacted> --- util.c | 28 +++++++++++++++++----------- 1 file changed, 17 insertions(+), 11 deletions(-)diff --git a/util.c b/util.c index c38ede7..5c845a0 100644 --- a/util.c +++ b/util.c@@ -710,17 +710,23 @@ int check_raid(int fd, char *name) if (!st) return 0; - st->ss->load_super(st, fd, name); - /* Looks like a raid array .. */ - pr_err("%s appears to be part of a raid array:\n", - name); - st->ss->getinfo_super(st, &info, NULL); - st->ss->free_super(st); - crtime = info.array.ctime; - level = map_num(pers, info.array.level); - if (!level) level = "-unknown-"; - cont_err("level=%s devices=%d ctime=%s", - level, info.array.raid_disks, ctime(&crtime)); + if (st->ss->add_to_super != NULL) { + st->ss->load_super(st, fd, name); + /* Looks like a raid array .. */ + pr_err("%s appears to be part of a raid array:\n", + name);
Code lines are 80 characters - again when moving code around like this,
please do it properly.
quoted hunk
+ st->ss->getinfo_super(st, &info, NULL); + st->ss->free_super(st); + crtime = info.array.ctime; + level = map_num(pers, info.array.level); + if (!level) level = "-unknown-";
if () and action should never be on the same line. Yes I know it was in
the old code, but then please fix it up when you move it around.
+ cont_err("level=%s devices=%d ctime=%s",
+ level, info.array.raid_disks, ctime(&crtime));
The indentation here is not acceptable, please do it properly like you
would in the kernel too.
+ }
+ else {Ehm?
quoted hunk
+ /* Looks like GPT or MBR */ + pr_err("partition table exists on %s\n", name); + } return 1; }
Cheers, Jes