Thread (10 messages) 10 messages, 4 authors, 2014-02-14

Re: Automatically drop caches after mdadm fails a drive out of an array?

From: Mikael Abrahamsson <hidden>
Date: 2014-02-13 17:25:59

On Thu, 13 Feb 2014, Andrew Martin wrote:
Note that I added a new, replacement drive to the array at 17:09. In 
lieu of Marvel SAS cards, what would you recommend?
LSI 2008 is very well tested HBA controller, it exists in many vendors' 
cards. Works properly with 4TB drives (and larger I presume). For instance 
the LSI SAS 9211-8i HBA has this chip.

-- 
Mikael Abrahamsson    email: swmike@swm.pp.se
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help