Thread (8 messages) 8 messages, 4 authors, 2014-01-02

Re: How to prefer some devices over others in raid

From: NeilBrown <hidden>
Date: 2014-01-01 07:05:17

On Wed, 1 Jan 2014 07:50:24 +0100 Tomas M [off-list ref] wrote:
My main concern is that I'm not always 100% sure if a certain drive is
the root cause of slow read performance, so failing a wrong one would
have terrible consequences. On the other hand, if it was possible to
say "read the data with pretending one drive has failed, but write to
the array as if all drives are ok", then I could actually find out if
copying speed reverts to normal.

Maybe I should write a kernel patch to try this out. Any suggestions
where to start?
raid1.c already has functionality like this, referred to as "Write-mostly".

To add it to raid5.c you would need to modify fetch_block().
It sets Wantread or Wantcompute to indicate the the block should be read, or
computed from others (which is only allows of all the others are valid
already).

So in the case where one device is write-mostly and no other devices are
faulty, it should set Wantread on all those other devices.
Once they have been read, fetch_block will be called again and the current
code will notice that setting Wantcompute is sufficient.

NeilBrown

Tomas M

On Tue, Dec 31, 2013 at 4:17 PM, Stan Hoeppner [off-list ref] wrote:
quoted

On 12/31/2013 8:42 AM, Tomas M wrote:
quoted
I'm using software raid 5 (stripe with one parity drive).

Is there a way to force the raid array to MOSTLY ignore one of the drives?

Let me explain. If a drive is failing (is very slow, has errors, etc),
then I still prefer to keep it in the array and simply COPY all data
from the array somewhere else, instead of risking that the array gets
degraded if I remove the failing drive and another one dies at the
same time.

Example:
- 4 drives in raid5
- one drive is slow, lets call the drive DISK1
- copying all data from the array is very slow because it still uses
DISK1 to read data from it, even if it could IGNORE it and COMPUTE the
data from the other three drives

The filesystem on the array needs to be still mounted rw, though,
since there may be some changes.

Is there any mdadm parameter or option which would make the array
IGNORE any given disk on reads (since those can be computed from other
drives), while still NOT IGNORING the disk in writes?

Because if I set it to ignore that failing slow drive, I will copy out
the data 100 times faster while still keeping the array in sync.
Because for me if ANOTHER drive dies, it will still be better to have
the data 100 times slower than nothing. I hope you understand me :)
The option you request is not available TTBOMK.  So...

Fail the drive.  Copy all the data off the array.  Zero the drive and
add it back.  Resync.

But while you're at it, why not simply replace the flaky drive before
the resync?  Why would you intentionally keep a known-to-be-failing
drive in the array?

--
Stan
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
  

Attachments

Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help