Re: [Recovery] RAID10 hdd failureS help requested
From: Karel Walters <hidden>
Date: 2013-09-24 18:18:39
Hi Phil, Thank you for all the great help so far!
Yes, that dmesg did the trick. The drive that failed first was #3, and the drive the failed second was #4. You should create a list of which drive serial number corresponds to which raid device role, with a third column showing the current device name.
Serial no: old name ID current name WD-WCC1T1255024 /dev/sdc1 new drive W1F09XLV /dev/sdb1 [3] /dev/sdd1 failed drive 1 W1F0AXTQ /dev/sdc1 [4] /dev/sde1 failed drive 2 W1F0B6X6 /dev/sdd1 [0] /dev/sdf1 S1F04BZT /dev/sde1 [5] /dev/sdg1 W1F0B9ER /dev/sdf1 [2] /dev/sdh1 WD-WMC1T2341606 /dev/sdg1 [1] /dev/sdi1 S1F04CWH /dev/sdh1 [6] /dev/sdj1 (partially rebuild spare)
Then, to deal with the large number of pending events, you'll need to do a "check" scrub with a very low speed limit. To keep you from exceeding the 10/hour read error limit in the MD kernel driver.
echo 1000 > /proc/sys/dev/raid/speed_limit_min echo 10000 > /proc/sys/dev/raid/speed_limit_max echo check > /sys/block/md0/md/sync_action Would this be ok in such a case? Karel