Re: Help with recovering a RAID5 array
From: Stefan Borggraefe <hidden>
Date: 2013-05-02 13:14:27
Am Donnerstag, 2. Mai 2013, 13:30:22 schrieb Mathias Burén:
I won't scold you for using RAID5 instead of RAID6 with this number of if drives and especially the size of the drives. Could you please post the output of smartctl -a for each device? (from smartmontools) That way we can verify which HDDs are broken, before proceeding. Mathias
Hello Mathias, RAID6 would have been the safer option clearly, but we needed the extra-space and only had this number of drives available. Here the requested output: smartctl -a /dev/sdc smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes Logical Unit id: 0x5000cca22bd08a85 Serial number: PK2331PAH5D0YT Device type: disk Local Time is: Thu May 2 15:09:16 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging smartctl -a /dev/sdd smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes Logical Unit id: 0x5000cca22bc3effb Serial number: PK2331PAG8NHZT Device type: disk Local Time is: Thu May 2 15:09:19 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging smartctl -a /dev/sde smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes Logical Unit id: 0x5000cca22bc3ff79 Serial number: PK2331PAG8TMXT Device type: disk Local Time is: Thu May 2 15:09:23 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging smartctl -a /dev/sdf smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes ^[[3~Logical Unit id: 0x5000cca22bc419ef Serial number: PK2331PAG90PET Device type: disk Local Time is: Thu May 2 15:09:25 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging smartctl -a /dev/sdg smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes Logical Unit id: 0x5000cca22bc2fe51 Serial number: PK2331PAG6L49T Device type: disk Local Time is: Thu May 2 15:09:27 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging smartctl -a /dev/sdh smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-37-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: Hitachi Product: HUS724040ALE640 Revision: MJAO User Capacity: 4.000.787.030.016 bytes [4,00 TB] Logical block size: 512 bytes Logical Unit id: 0x5000cca22bc2fe2d Serial number: PK2331PAG6L34T Device type: disk Local Time is: Thu May 2 15:09:30 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: <not available> Error Counter logging not supported Device does not support Self Test logging -- Best regards, Stefan Borggraefe -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html