Re: Trouble adding disk to degraded array
From: Phil Turmel <hidden>
Date: 2013-01-12 00:24:30
From: Phil Turmel <hidden>
Date: 2013-01-12 00:24:30
On 01/11/2013 07:01 PM, Nicholas Ipsen wrote:
Yikes, I may really have stepped in it with that filesystem check...
[trim /]
Note that this is not the device that was giving me trouble before, nor is it the on I replaced it with. What have I done wrong here?
Are you also getting errors from the controller/drive? If so, you might have a hardware problem, like a power supply going bad (writing draws significantly more power than reading). Please post your latest complete dmesg. Phil