Re:
flat view
From: Phil Turmel <hidden>
Date: 2012-12-26 02:15:35
On 12/25/2012 07:16 PM, bobzer wrote:
thanks to help me
No problem, but please *don't* top-post, and *do* trim replies. Also, use reply-to-all on kernel.org mailing lists.
root@debian:~# mdadm -E /dev/sd[bcd]1
/dev/sdb1:
Magic : a92b4efc
Version : 1.2
Feature Map : 0x0
Array UUID : bf3c605b:9699aa55:d45119a2:7ba58d56
Name : debian:0 (local to host debian)
Creation Time : Sun Mar 4 22:49:14 2012
Raid Level : raid5
Raid Devices : 3
Avail Dev Size : 3907021954 (1863.01 GiB 2000.40 GB)
Array Size : 7814043136 (3726.03 GiB 4000.79 GB)
Used Dev Size : 3907021568 (1863.01 GiB 2000.40 GB)
Data Offset : 2048 sectors
Super Offset : 8 sectors
State : clean
Device UUID : 5e71f69a:a78b0cd7:bbbb7ecb:cf81f9f6
Update Time : Tue Dec 25 06:25:02 2012
Bad Block Log : 512 entries available at offset 2032 sectors
Checksum : 922ddaa8 - correct
Events : 413
Layout : left-symmetric
Chunk Size : 128K
Device Role : Active device 0
Array State : A.. ('A' == active, '.' == missing)
mdadm: No md superblock detected on /dev/sdc1.
mdadm: No md superblock detected on /dev/sdd1.This is bad. The two disks are still offline. You must find and fix the hardware problem that is keeping these two disks from communicating. Unless the two disks suffered a simultaneous power surge, the odds they are OK is good. But look at your cables, controller, or power supply.
I would like to understand too dmesg (with the begin removed) show a lot of error : http://pastebin.com/D1D8AKF9
I browsed it: all attempts to communicate with those two drives failed. That must be fixed first. Then we can help you recover the data. If you can plug the three drives into another machine, that would be the simplest way to isolate the problem. HTH, Phil